NIR INSPECTION – NEAR INFRARED SPECTROSCOPY SYSTEM

DON’T BE FOOLED BY APPEARANCES

SEA Vision brand new Near Infrared Reflectance (NIR) solution HarleNIR is based on Harlequin blister control system. The new revolutionary system is able to perform a chemical composition inspection on pharmaceutical products during the production process.

Thanks to integrated imaging technology HarleNIR can distinguish products directly from their active ingredients. The spectral control acquires the value of spectral bands for each single pixel of an image, in order to identify and distinguish similar products not in terms of shape and colour but in terms of chemical compound.

Thanks NIR Near infrared Reflectance chemical analysis, it is then possible to:

► identify drugs with different active principle (qualitative analysis)

► identify drugs with different dosage or measure their active ingredient uniformity distribution (quantitative analysis)

TECHNICAL INFORMATION:

  • In-line API inspection
  • Non-destructive analysis
  • 100% of products inspected
  • Analysis of multiple components at the same time
  • Accurate results in real time
  • Image acquisition speed performance up to 15000 frame/sec

RESOURCES

Watch here the full interview to Vittorio Calbucci, our Product Specialist, physicist and part of our R&D team – speaks about the #Spectroscopy and the #ChemicalImaging applied to the #pharmaceutical production.

Resources

download

Contact us to receive the complete brochure

Name and Surname (*)

Company (*)

Email (*)

Telephone (*)

Message

LEARN FROM HARLENIR CASE STUDIES THE SYSTEM TYPICAL APPLICATIONS

  • null

    CRACKS/COATING

     Detection of crack on tablets or absence of coating or part of coating.
  • null

    ACTIVE PRINCIPLE DISTRIBUTION TABLETS

    Distribution of the API inside the tablet respect the excipients.
  • null

    API DISTRIBUTION CAPSULES

    Measure of the active principle distribution inside the capsules.

  • null

    CAPSULES OVERLAPPING AREA

     The red stripe illustrates the overlapping area. The capsules on the left have less overlapping area if compared with the capsules on the right.
  • null

    MIXED TABLETS INSPECTION

    Mixed Tablets inside the same blister

HARLENIR TECHNICAL SPECIFICATIONS

Thanks to NIR technology it is possible to perform common pharmaceutical quality-controls on drugs. The HarleNIR hyperspectral system uses the chemical compound presents inside a particular sample to distinguish and identify materials. Traditionally QA has relied on laboratory-based analytical techniques which can be now handled at one time to obtain 100% safe products. Find Below the system technical specifications.

SPECTRAL RANGE 900 – 1700 nm
SPECTRAL BANDS 224
SPECTRAL RESOLUTION 3.5 nm
SPATIAL PIXELS 640
SPEED FRAME ACQUISITION 670 frame/sec (full frame)  – 15000 frame/sec
TABLETS INSPECTION DEPTH Around 200 microns for tablets (capsules can be completely get through)
LIGHT UNIT Halogen light
ACCURACY Less than 0.3 mg for 1 gram of API

Contact us

Email: marketingdept@seavision.it

Tel:+39.0382.529576

Fax:+39.0382.527260